Transmissive Panel Covers (TPC)

Control Risk with Infrared Transmissive Panel Covers
Thermographers can identify loose connections and other anomalies in PDUs, but typically dead-front panels must be removed to allow a clear view of connections. Removing the panel covers on electrical equipment over 50V requires use of PPE and carries the very real risk of dislodging breakers which could bring a facility and its profitability to their knees.
Non-invasive thermography through the patented optic in the Infrared Transmissive Panel Covers (TPC series) from IRISS provides thermographers with the visibility they need without any added risk to personnel or plant. Inspections will take a fraction of the time and can be performed during peak loading for meaningful data.
Ask your IRISS representative how these custom sized solutions can be the next invaluable tool in your Electrical Preventive Maintenance Program.
Protected by an Unconditional Lifetime Warranty.


TPC Features
- Custom sized to fit your application
- Based on the same patented designs used in standard IRISS infrared windows
- Thermographers gain full access to view connections, without the risks associated with panel removal
The Transmissive Panel Cover (TPC) solution from IRISS was specifically designed to exceed the demands of the industrial and building maintenance community. The window panes are impact resistant and maintain a Fixed and Stable IR transmission rate.
The TPC series uses the same patented design and construction as the VPFR industrial-grade viewing panes – the ONLY impact resistant IR windows on the market today.
Compare the durability of the patented VPFR Industrial-Grade Viewing Pane…
…To that of a typical Calcium Fluoride optic.
The IRISS Industrial-Grade TPC solution was specifically designed to exceed the demands of the industrial and building maintenance community of impact resistant IR windows with stable transmission rate. The TPC optic material is unaffected by humidity, moisture, vibration, high frequency noise and a broad spectrum of acids and alkalis.
Because of the materials we use, IRISS is the only infrared window manufacturer that is able to offer a true, Unconditional Lifetime Warranty.
Specifications
Material
|
Panel & Reinforcing Grill |
Specified to suit customer requirements |
|
Optic |
UL 746C certified, IR transmissive polymer; |
Pricing and availability vary based on size and complexity of panel. For more information contact your IRISS representative.
Control Risk While Inspecting Power Distribution Panels (PDUs)
Removing the dead-front panels from PDUs to inspect breaker connections is risky business. The IRISS TPC solutions allow thermographers to inspect breaker connections while leaving the dead-front panel in place. The result is a safer, faster and virtually risk-free inspection that can enable thermographers to catch otherwise hidden faults before they result in costly downtime.
Our clients are using the TPC Solution extensively in PDU Panels:
- Office Complexes
- Banks
- Trading Houses
- Computer Data Centers
Other industries:
- Refineries
- Paper Mills
- Utilities
- Pharmaceuticals
- Computer Data Centers
- Steel Mills
- Aluminum Plants
- Etc

Pricing is all custom based on size and complexity of the solution and based on the types of materials used. Below is an

example of a typical TPC solution:
|
Description |
1st Piece prototype |
10 Identical Pieces Based on Approved Prototype |
|
The TPC range of products is Infinite... send us your requirements and allow us to quote directly to you today!! |